Home Home
shopping cart View Cart  | Español Hablamos Español
|      HOME      |      ABOUT US      |      OUR PRODUCTS      |      REQUEST A QUOTE      |      CONTACT US      |     

 

 

Leroy Somer R448 AVR Automatic Voltage Regulator

 Leroy Somer R448 AVR

LEROY SOMER R448 AVR FOR LEROY SOMER ALTERNATORS
LEROYSOMERAEM110RE016, 922-124


Leroy Somer R448 has been replaced with the R450 regulator. Please click on the picture below




Leroy Somer R450 AVR Automatic Voltage Regulator


General Description / Specifications


For both AREP & PMG excitation systems,the alternator voltage regulator is the R 448. With AREP excitation, the R 448 electronic AVR is powered by two auxiliary windings which are independent of the voltage equal circuit. The primary winding has a voltage in ratio to that of the alternator (characteristic Shunt), the next has a voltage in proportion to the stator current (compound characteristic: Booster effect).The power supply voltage is rectified and filtered before being used by the AVR monitoring transistor. With PMG excitation, a permanent magnet generator (PMG) added to the alternator supplies the AVR with voltage which is free of the main alternator winding. This is built-in at the rear of the machine and connected to the R 448 AVR, and the ST9 jumper must be disconnected. These two principles provide the machine with a short-circuit current capacity of 3 IN for 10 s, and good protection to distortions generated by the load. The AVR monitors and corrects the alternator output voltage by adjusting the excitation current. In SHUNT excitation, R 448 AVR.is supplied by main windings (140V - 50/60 Hz) to X1, X2.


On application of a load, the rotation speed of the generator set decreases. When it passes below the preset frequency threshold the LAM causes the voltage to drop by approximately 13% or 25% and consequently the quantity of active load applied is reduced by approximately 25% to 45%, until the speed reaches its rated value again. Hence the LAM can be used either to reduce the speed variation (frequency) and its duration for a given applied load, or to increase the applied load probable for one speed variation (turbo-charged engine).

To avoid voltage oscillations, the trip threshold for the LAM function should be set approximately 2 Hz below the lowest frequency in steady state. It is advisable to use the LAM at 25% for load impacts 70% of the genset rated power.LAM, action eliminated by cutting the ST5 jumper. During load impacts, the function helps the genset to return to its rated speed faster thanks to a gradual increase in voltage according to the
principle:

> If the speed drops between 46 and 50 Hz, the rated voltage follows a
fast gradient as it is restored.

> If the speed drops below 46 Hz, since the engine needs more help, the
voltage follows a slow gradient as it returns to the reference value.

The new functions of the R448 are :
- Parallel operation between alternators with C.T.
- Parallel operation with the mains with C.T.and R 726 module
- 3-phase sensing (R 731 module)
- LAM function integrated in the R 448 AVR.



QUOTATION CENTER

(Please Enter Your Email Below To Receive A Quote)

TECHNICAL INFORMATION AND RESOURCES

(Download Datasheet)
STANDARD TERMS & CONDITIONS:
NEW and ORIGINAL parts
Each unit prototype and individually tested from factory prior to shipping
Shipping world wide via FedEx, UPS, DHL, USPS, TNT
Same day shipping subject to previous sales
Photos reflect most curret model and features
Great discounts available for volume orders, Distributors welcome
GENERAL POWER stocks 300+ diesel generators form 6 to 1000Kw Miami Florida, Tustin California, Panama, Colombia, France, UK
Diesel Generators
    10 kw to 40 kw diesel generators
    45 kw to 95 kw diesel generators
    100 kw to 175 kw diesel generators
    200 kw to 350 kw diesel generators
    400 kw to 600 kw diesel generators
    650 kw to 2000 kw diesel generators
Automatic Voltage Regulators
    Meccalte AVR
    Kohler AVR
    Kipor AVR
    Grameyer AVR
    Leroy Somer AVR
    Newage AVR
    Stamford AVR
    Marathon AVR
    Basler AVR
    Generac AVR
    Marelli AVR
    Delco AVR
Transfers Switches
    ASCO Automatic Transfer Switch
    Genpower Automatic Transfer Switch
    SDMO Automatic Transfer Switch
    Zenith Automatic Transfer Switch
Alternators
    Stamford Generator End
    Marathon Electric Generator End
    Leroy Somer Generator End
    Marelli Generator End
    MeccAlte Generator End
Generator Parts
    Generator Fuel Tanks
    Generator Trailers
    Generator Automatic Battery Chargers
    Generator Engine Heaters
    Diesel Engine Parts
    Alternator Parts
    Generator Control Panels
    Generator Enclosures
    Generator Engine Filters
JOHN DEERE Diesel Generators
CUMMINS Diesel Generators
SDMO Diesel Generators
BROADCROWN Diesel Generators
MITSUBISHI Diesel Generators
KOHLER Diesel Generators
LISTER PETTER Diesel Generators
DETROIT MTU Diesel Generators
CATERPILLAR Diesel Generators
VOLVO Diesel Generators
ONAN Diesel Generators
GENERAL POWER Diesel Generators
KUBOTA Diesel Generators
OTTOMOTORES Diesel Generators
INDUSTRIAL Diesel Generators
COMMERCIAL Diesel Generators
BACKUP Diesel Generators
EMERGENCY Diesel Generators
PORTABLE Diesel Generators
STANDBY Diesel Generators
ELECTRIC Diesel Generators
HIMOINSA Generators
HIPOWER Diesel Generators
GENERAC COMMERCIAL GENERATORS
PLANTAS ELECTRICAS
PLANTAS ELECTRICAS VENEZUELA
PLANTAS ELECTRICAS COLOMBIA
GENERATOR SALES
Home
  ABOUT US
Contact us
Terms
GENERAL POWER LIMITED, INC
8145 N.W. 33rd Street
Miami, Florida 33122
P (305) 471 9566 P (888) POWER58 F (305) 471 9568
Copyright © - 2014 All images and marks in this site are property of their respective owners.