Thank you for choosing our line of HIPOWER Generators, powered by John Deere, Yanmar, and Volvo engines:
|
|
| |
|
45KW DIESEL GENERATOR 45KVA, HIPOWER HYW45M6 DIESEL GENERATOR SET
43Kw (43Kva) Standby, 39Kw (39Kva) Prime, 60Hz, 1800RPM, 1 Phase, 1.0PF
- YANMAR 4TNV98T diesel engine, Turbocharged, heavy duty, 4 stroke, 1800rpm, Liquid cooled, EPA Tier 4 compliant
- STAMFORD PI144K, brushless alternator. IP23 drip-proof protection, Insulation class H. Automatic voltage regulation
- MERLIN GERIN / SCHNEIDER, Main line circuit breaker, 2pole, set mounted, wired and output rated for maximum generator protection
- HIPOWER CEM7, Digital auto-start control panel. All genset parameters, alarms, control functions and indicators. CE and UL listed
60 HERTZ, 1 PHASES, 1.0PF, 1800 RPM
|
 |
|
|
Voltage
|
Power ESP
kWe/kVA
|
Power PRP
kWe/kVA
|
Standby Amps
|
Dimensions
|
Weight
|
|
|
|
|
|
|
240/120
|
43 / 43
|
39 / 39
|
179
|
Length: 1950mm [76.8in]
|
605kg [1336lbs] Net
|
|
|
|
|
Width: 780mm [30.7in]
|
702kg [1548lbs] Gross
|
|
|
|
|
Heigth: 1280mm [50.4in]
|
|
45 KW GENERATOR, FULLY PACKAGED, READY TO START INCLUDES:
- Open skid mounted version (a)
- U.S. EPA Tier 4 compliant engine as per the U.S. Environmental Protection Agency regulations (b)
- 2-wire Auto Start control included standard for operation with ATS Automatic Transfer Switch and AMF Automatic Mains Failure systems
- Base-frame Incorporated metallic fuel tank, single wall. High capacity: 115L (30Gal), 10hours @ ¾ (c)
- Turbocharged 1800rpm diesel engine optimized for longer life, low maintenance, heavy duty use and demanding power generation applications
- Single bearing alternator, self excited, IP23, Insulation class H/H, AVR SX460 automatic voltage regulation (d)
- Radiator for wiring T°of 50°C [122°F] max with mechanical fan
- Microprocessor control panel
- 12V charging alternator and starter
- 12V charged DC starting battery with electrolyte and cables
- Battery quick disconnect switch installed
- 9dB(A) Industrial class silencer mounted and installed. Muffler individually protected by hot parts grill for operator safety
- Cartridge type heavy duty 2 stage air filter, fuel filter and oil filter elements installed
- Water/Fuel separator pre-filter decanter for fuel debris and water condensation installed
- Mechanical oil elevation pump for effortless oil change and maintenance
- Mechanically welded chassis with anti-skid vibration isolators
- User guide, commissioning and Maintenance manual. Wiring diagrams included (English and Spanish)
- Each genset is prototype and individually factory tested prior to shipping with load banks, performance certificates provided free of charge
- The generator accepts 100% rated load in one step as per NFPA110 and meets ISO8528-5 class G-3 for transient response
- The generator meets NFPA110, Level 1 when equipped with the corresponding accessories and installation guidelines
- 2 years parts and labor or 2000 hours limited warranty, whichever occurs first
- All other Standard features, please see catalog or contact us for details
- Fully customizable and many options available: Steel and Aluminum generator enclosures, 30 - 10,000Gal fuel tanks, 30 - 4,000Amp Manual and Automatic Transfer Switches and Many more!
- Compliant with ISO8528, BS4999, ISO3046, BS 5514, BS5000PT99, AS 1359, IEC34, VDE0530, UTE5100, and ISO9001 : 2000
(a) Also available in weather proof, sound attenuated enclosure version (Steel and Aluminum)
(b) Also available in non EPA compliant version optimized for low fuel consumption
(c) Fuel consumption calculated on 75% prime power consumption, extended capacity fuel tanks from 20 to 5000Gal are also available (d) Permanent Magnet Generator (PMG) upgrade available on all Stamford Alternators
ESP: The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed.
PRP: Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1.
HIPOWER GENERATOR, is a subsidiary of HIMOINSA, and one of the World TOP 10 leaders in the manufacture of Diesel Generator sets from 10 to 2000 KW!
With a distributor network present in over 100 countries, HIPOWER specializes in the power range of 20KW to 500KW. With factory presence in every continent, Each Hipower Genset is manufactured and assembled using only the industry's most reliable and tested components which includes:
John Deere engines
Yanmar diesel engines
Volvo diesel engine
Iveco engines
MTU engines
Stamford alternators
Deep Sea control panels
Merlin Gerin / Schneider breakers
HIMOINSA S.L., in its constant effort to become the leader in Power Generation systems, commits every year over 5% of its revenues to research and development of its products. In a similar effort, every HiPower Genset complies to all major industrial performance and quality control certifications which include: ISO3046, BS4999, ISO8528, BS 5514, BS5000PT99, IEC34, AS1359, UTE 5100, VDE0530 and ISO9001 2000
GENERAL POWER stocks 100+ Diesel Generator sets from 20 KW Generator to 500KW ready for same day shipping from our Miami, Florida distribution center. Hundreds of customers trust General Power every year with their power generation and Standby Generator needs. All major generator set brands, power sizes, Automatic Transfer Switches, Sub base fuel tanks, Battery chargers, Engine preheaters, Filter kits and Trailers are kept in stock to meet even your most urgent needs. We have recently sold and are currently serving among many others:
| Florida |
Ohio |
Nebraska |
Alabama |
Michigan |
Oklahoma |
| Texas |
New Jersey |
Alabama |
Puerto Rico |
US Virgin Islands |
Oregon |
| South Carolina |
Massachusetts |
Utah |
Kansas |
Indiana |
Florida |
| North Carolina |
St. Croix, U.S.V.I |
Colorado |
Ohio |
Iowa |
Washington |
| California |
St. John U.S.V.I |
Arizona |
Montana |
Virginia |
California |
| Georgia |
St. Thomas, U.S.V.I |
Arkansas |
Hawaii |
Texas |
exporting worldwide! |
HIPOWER HYW45M6 are powered by YANMAR 4TNV98T Engines:
U.S. EPA Tier 4 compliant
Based on the proven success of the TNE engine series, Yanmar has achieved greater exhaust emissions by improving the combustion chamber and fuel injection equipment design.
The Yanmar 4TNV98T-ZGGE Engines are compliant as per U.S. EPA Tier 4 and EU stage III A emissions regulations.
Fuel Injection and Low Consumption
Using new technology in line MP fuel injection pumps a more precise delivery and control is achieved.
The final result is lower emissions and improved performance on many different applications as well as above excellent fuel economy.
Low Sound Levels
Yanmar's unique CAE methods have fin tuned the block stiffness, lowered to a minimum transformation, and reduced radiant sound levels in the cylinder block.
Using and improved gear tooth profile directly results in lesser mechanical noise and gear sound levels.
|
|
QUOTATION / ORDER CENTER
(Please indicate the desired quantity for each product) |
DELIVERY: In stock |
|
|
| |
STANDARD TERMS & CONDITIONS: |
|
Prices reflect factory standard voltage and configuration
Prices reflect 4% discount for wire transfer or check payment
Lead time and stock are subject to previous sales
Other Standard Terms & conditions will apply
|
|
| |
|
HIPOWER YANMAR authorized distributor |
|
|
Commercial finance & leasing |
|
|
GENERAL POWER stocks 300+ diesel generators form 6 to 1000Kw
Miami Florida, Tustin California, Panama, Colombia, France, UK
|
|
|
|
|
|
|